* feat: Add state sync and use it to remember viewport grid info fix: Version updates Fixes for toggling MPR mode Fix the display when the interleaved load module fails Fix the memory of the state to restore correctly PR fixes for the state sync service PR fixes PR fixes PR fixes Added a hack warning to remove volumeDeactivate Fixes for TMTV colormap setting Fix the casing Missed renames fix: tests not running due to variance in ordering Reverting some fixes to change case PR changes - mostly comments and minor improvements fix: All display sets were being updated on drag and drop PR fixes - mostly renames PR fixes Test support for OHIF, for HP branch test: Add at least a minimal set of automated tests for hanging protocols Docs PR fixes Merge fixes DOCS updates Add an example of the mn hanging protocol PR fixes PR fixes PR fixes * Fix the drag and drop PR fixes * PR changes - update default keys for next/previous stage * fix: Was storing the custom viewport grid too aggressively Caused by a PR change misspelling a variable |
||
|---|---|---|
| .. | ||
| .webpack | ||
| assets | ||
| src | ||
| babel.config.js | ||
| LICENSE | ||
| package.json | ||
| README.md | ||
Measurement Tracking Mode
Introduction
Measurement tracking mode allows you to:
- Draw annotations and have them shown in the measurement panel
- Create a report from the tracked measurement and export them as DICOM SR
- Use already exported DICOM SR to re-hydrate the measurements in the viewer
Workflow
Status Icon
Each viewport has a left icon indicating whether the series within the viewport contains:
- tracked measurement OR
- untracked measurement OR
- Structured Report OR
- Locked (uneditable) Structured Report
In the following, we will discuss each category.
Tracked vs Untracked Measurements
OHIF-v3 implements a workflow for measurement tracking that can be seen below. In summary, when you create an annotation, a prompt will be shown whether to start tracking or not. If you start the tracking, the annotation style will change to a solid line, and annotation details get displayed on the measurement panel. On the other hand, if you decline the tracking prompt, the measurement will be considered "temporary," and annotation style remains as a dashed line and not shown on the right panel, and cannot be exported.
Below, you can see different icons that appear for a tracked vs. untracked series in OHIF-v3.
Reading and Writing DICOM SR
OHIF-v3 provides full support for reading, writing and mapping the DICOM Structured Report (SR) to interactable Cornerstone Tools. When you load an already exported DICOM SR into the viewer, you will be prompted whether to track the measurements for the series or not.
If you click Yes, DICOM SR measurements gets re-hydrated into the viewer and the series become a tracked series. However, If you say no and later decide to say track the measurements, you can always click on the SR button that will prompt you with the same message again.
The full workflow for saving measurements to SR and loading SR into the viewer is shown below.
Loading DICOM SR into an Already Tracked Series
If you have an already tracked series and try to load a DICOM SR measurements, you will be shown the following lock icon. This means that, you can review the DICOM SR measurement, manipulate image and draw "temporary" measurements; however, you cannot edit the DICOM SR measurement.